Assessment Year | 1982 |
---|---|
Principal Product | THERMOFORMED PLASTIC |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 400 |
Plant Area |
n/a
|
Annual Production | 1,550,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $847,982 | 25,145,956 |
kWh
|
$0.034 |
Natural Gas | $33,564 | 9,424 |
MMBtu
|
$3.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,846 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,846 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,021 | $400 |
$2,021
60,082
kWh
|
|
02 | 2.7111: Reduce illumination to minimum necessary levels | $9,712 | - |
$9,712
288,101
kWh
|
|
03 | 2.2694: Use highest temperature for chilling or cold storage | $1,841 | - |
$1,841
54,513
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,272 | $150 |
$15,272
452,814
kWh
|
|
TOTAL RECOMMENDED | $28,846 | $550 |
$28,846
855,510
kWh
|
||
TOTAL IMPLEMENTED | $28,846 | $550 |
$28,846
855,510
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs