| Assessment Year | 1994 |
|---|---|
| Principal Product | Injection Molded Plastics |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 146 |
| Plant Area |
48,790
ft2
|
| Annual Production | 12,060,864
pieces
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | South Dakota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $128,323 | 3,169,988 |
kWh
|
$0.040 |
| Natural Gas | $14,812 | 3,326 |
MMBtu
|
$4.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,520 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,243 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,239 | $12,100 |
$6,239
154,162
kWh
|
- | |
| 02 | 2.7135: Install occupancy sensors | $1,571 | $5,863 |
$1,571
45,135
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $4,004 | $9,745 |
$4,004
98,769
kWh
|
- | |
| 04 | 2.7231: Use radiant heater for spot heating | $3,587 | $7,200 | - |
$3,587
-
MMBtu
|
|
| 05 | 2.2511: Insulate bare equipment | $13,284 | $230 |
$13,284
328,839
kWh
|
- | |
| 06 | 2.3191: Use demand controller or load shedder | $3,835 | - |
$3,835
-
kWh
|
- | |
| TOTAL RECOMMENDED | $32,520 | $35,138 |
$28,933
626,905
kWh
|
$3,587
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,243 | $21,845 |
$10,243
252,931
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs