| Assessment Year | 2010 |
|---|---|
| Principal Product | Plastic Containers |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | less than $500 k |
| # of Employees | 100 |
| Plant Area |
9,999
ft2
|
| Annual Production | 9,999
units
|
| Production Hrs. Annual | 7,365
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $899,422 | 12,474,416 |
kWh
|
$0.072 |
| LPG | $25,942 | 1,352 |
MMBtu
|
$19.19 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $94,684 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,319 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $65,458 | $79,125 |
$65,458
896,689
kWh
|
|
| 02 | 2.2511: Insulate bare equipment | $12,645 | $14,080 |
$12,645
173,225
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $2,705 | $422 |
$2,705
75,162
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,957 | $26,400 |
$6,957
193,184
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,557 | $8,750 |
$2,557
71,016
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,362 | $21,600 |
$4,362
121,182
kWh
|
|
| TOTAL RECOMMENDED | $94,684 | $150,377 |
$94,684
1,530,458
kWh
|
||
| TOTAL IMPLEMENTED | $11,319 | $48,000 |
$11,319
314,366
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs