ITAC Assessment: CW0126
ITAC logo
ITAC Assessment: CW0126
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Actuators for the oil, natural gas, mining and chemical industries
NAICS 333995: Fluid Power Cylinder and Actuator Manufacturing
SIC 3593: Fluid Power Cylinders and Actuators
Sales Range $50
M
to 100
M
# of Employees 150
Plant Area 540,000
ft2
Annual Production 1,000,000
units
Production Hrs. Annual 4,380
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $64,912 1,138,800
kWh
Electricity Demand $46,226 4,918
kW-mo/yr
Electricity Fees $111,137 -
Natural Gas $41,597 9,306
MMBtu
Waste Disposal Costs
Water Usage $13,757 559,200
Tgal
TOTAL YEARLY COSTS $277,628
RECOMMENDED SAVINGS* $63,508 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.7491: Insulate glazing, walls, ceilings, and roofs $17,675 $20,960 $(-527.3)
9,250
kWh
- - $18,202
-
MMBtu
-
02 2.7491: Insulate glazing, walls, ceilings, and roofs $12,461 $15,547 - - - $12,461
-
MMBtu
-
03 2.4322: Use or replace with energy efficient substitutes $361 - $(-145.6)
2,555
kWh
- - $305
-
MMBtu
$202
04 2.4133: Use most efficient type of electric motors $19,047 $54,963 $6,573
115,319
kWh
$12,473
-
kW-mo/yr
- - -
05 2.8227: Adjust / maintain fork lift trucks for most efficient operation $10,872 $33,000 - - - - $10,872
06 2.3137: Use power during off-peak periods $921 - - - $921 - -
07 2.9113: Use solar heat for heat $2,171 $13,500 $2,171
38,086
kWh
- - - -
TOTAL RECOMMENDED $63,508 $137,970 $8,071
165,210
kWh
$12,473
-
kW-mo/yr
$921 $30,968
-
MMBtu
$11,074
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs