Assessment Year 2004
Principal Product Contract fabricated metal parts
NAICS 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3499: Fabricated Metal Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 103,100
ft2
Annual Production 200
pieces
Production Hrs. Annual 5,096
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $52,752 1,970,185
kWh
Electricity Demand $74,260 5,599
kW-mo/yr
Electricity Fees $1,500 -
Natural Gas $58,915 9,694
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $22,280 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,330

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2437: Recover waste heat from equipment $4,630 $1,790 - - $4,630
-
MMBtu
02 2.4239: Eliminate or reduce compressed air usage $3,590 $4,680 $1,830
69,400
kWh
$1,760
-
kW-mo/yr
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,360 $570 $1,200
45,600
kWh
$1,160
-
kW-mo/yr
-
04 2.2514: Cover open tanks $1,200 $750 $710
26,800
kWh
$490
-
kW-mo/yr
-
05 2.4239: Eliminate or reduce compressed air usage $880 $240 $550
20,900
kWh
$330
-
kW-mo/yr
-
06 2.2711: Utilize outside air instead of conditioned air for drying $300 $420 $150
5,700
kWh
$150
-
kW-mo/yr
-
07 2.7243: Improve air circulation with destratification fans / other methods $9,320 $27,720 $(-580.0)
(-22,100)
kWh
$(-400.0)
-
kW-mo/yr
$10,300
-
MMBtu
TOTAL RECOMMENDED $22,280 $36,170 $3,860
146,300
kWh
$3,490
-
kW-mo/yr
$14,930
-
MMBtu
TOTAL IMPLEMENTED $8,330 $6,660 $4,440
168,400
kWh
$3,890
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs