Assessment Year | 2003 |
---|---|
Principal Product | Metal missile cases |
NAICS | 332994: Small Arms, Ordnance, and Ordnance Accessories Manufacturing |
SIC | 3489: Ordnance and Accessories, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
56,730
ft2
|
Annual Production | 17,400
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,829 | 1,059,600 |
kWh
|
$0.039 |
Electricity Demand | $44,251 | 3,643 |
kW-mo/yr
|
$12.15 |
LPG | $13,330 | 1,586 |
MMBtu
|
$8.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,084 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $9,140 | $10,660 |
$3,660
93,600
kWh
|
$8,840
-
kW-mo/yr
|
$(-3,360.0)
-
MMBtu
|
- | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $4,420 | $10,000 | - |
$4,420
-
kW-mo/yr
|
- | - | - | |
03 | 2.3191: Use demand controller or load shedder | $4,300 | $840 | - | - | - | $4,300 | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $1,870 | $1,950 |
$1,960
50,000
kWh
|
$(-700.0)
-
kW-mo/yr
|
$610
-
MMBtu
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $170 | $414 |
$76
1,950
kWh
|
$112
-
kW-mo/yr
|
- | - | $(-18.0) | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $184 | $308 |
$68
1,716
kWh
|
$96
-
kW-mo/yr
|
- | - | $20 | |
TOTAL RECOMMENDED | $20,084 | $24,172 |
$5,764
147,266
kWh
|
$12,768
-
kW-mo/yr
|
$(-2,750.0)
-
MMBtu
|
$4,300 | $2 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs