Assessment Year | 1999 |
---|---|
Principal Product | particleboard |
NAICS |
n/a
|
SIC | 2493: Reconstituted Wood Products |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
140,000
ft2
|
Annual Production | 48,000,000
thousand feet
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | New Mexico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $721,833 | 16,961,020 |
kWh
|
$0.043 |
Electricity Demand | $311,769 | 31,224 |
kW-mo/yr
|
$9.98 |
Electricity Fees | $74,159 | - |
|
- |
Natural Gas | $198,909 | 58,141 |
MMBtu
|
$3.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $130,400 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $41,240 | $10,000 | n/a | - |
$41,240
-
kW-mo/yr
|
- | - | - | - | - | - | - |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,020 | $220 | n/a |
$4,690
118,992
kWh
|
$1,890
-
kW-mo/yr
|
- | - | - | $(-1,560.0) | - | - | - |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,640 | - | n/a |
$1,400
27,843
kWh
|
$1,240
-
kW-mo/yr
|
- | - | - | - | - | - | - |
04 | 2.4133: Use most efficient type of electric motors | $430 | $440 | n/a |
$310
7,913
kWh
|
$120
-
kW-mo/yr
|
- | - | - | - | - | - | - |
05 | 3.8132: Use less toxic and volatile solvent substitutes | $39,330 | - | n/a | - | - |
$(-70.0)
-
Tgal
|
$38,440
-
gal
|
- | - | - | $960 | - |
06 | 3.5314: Use in-process recycling whenever possible | $2,180 | $3,500 | n/a | - | - | - | - |
$280
-
lb
|
- | $1,900 | - | - |
07 | 4.624: Hire additional personnel to reduce changeout time | $39,560 | $1,000 | n/a | - | - | - | - | - | $(-40,000.0) | - | - | $79,560 |
TOTAL RECOMMENDED | $130,400 | $15,160 |
$6,400
154,748
kWh
|
$44,490
-
kW-mo/yr
|
$(-70.0)
-
Tgal
|
$38,440
-
gal
|
$280
-
lb
|
$(-41,560.0) | $1,900 | $960 | $79,560 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs