| Assessment Year | 2025 |
|---|---|
| Principal Product | Panelized building components, wall panels, roof trusses, floor systems, framing assemblies |
| NAICS | 321992: Prefabricated Wood Building Manufacturing |
| SIC | 2452: Prefabricated Wood Buildings and Components |
| Sales Range | $50 M to 100M |
| # of Employees | 50 |
| Plant Area |
205,377
ft2
|
| Annual Production | 445
units
|
| Production Hrs. Annual | 2,860
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $12,313 | 321,840 |
kWh
|
$0.038 | |
| Electricity Demand | $32,701 | 1,279 |
kW-mo/yr
|
$25.57 | |
| Electricity Fees | $4,305 | - |
|
- | |
| Natural Gas | $30,041 | 3,784 |
MMBtu
|
$7.94 | |
| LPG | $16,597 | 585 |
MMBtu
|
$28.35 | |
| Waste Disposal Costs | |||||
| Water Usage | $5,784 | 40,191 |
Tgal
|
$0.14 | |
| TOTAL YEARLY COSTS | $101,741 | ||||
| RECOMMENDED SAVINGS* | $59,395 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8226: Increase efficiency of trucks | $23,789 | $406,000 |
$(-2,887.0)
75,457
kWh
|
- | - |
$16,596
-
MMBtu
|
$10,080 | |
| 02 | 2.9114: Use solar heat to make electricty | $18,183 | $197,734 |
$8,800
230,005
kWh
|
$9,383
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $7,467 | $14,297 | - | - |
$7,467
-
MMBtu
|
- | - | |
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $4,486 | $42,000 |
$1,027
26,838
kWh
|
$3,094
-
kW-mo/yr
|
$365
-
MMBtu
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,237 | $1,015 |
$700
18,273
kWh
|
$2,537
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $2,027 | $37,800 | - | - |
$2,027
-
MMBtu
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $206 | $594 |
$53
1,390
kWh
|
$153
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $59,395 | $699,440 |
$7,693
351,963
kWh
|
$15,167
-
kW-mo/yr
|
$9,859
-
MMBtu
|
$16,596
-
MMBtu
|
$10,080 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs