| Assessment Year | 2024 |
|---|---|
| Principal Product | Thermoplastic Composites |
| NAICS | 325211: Plastics Material and Resin Manufacturing |
| SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
| Sales Range | $100 M to 500M |
| # of Employees | 90 |
| Plant Area |
114,000
ft2
|
| Annual Production | 13,000,000
units
|
| Production Hrs. Annual | 6,136
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $239,275 | 3,909,216 |
kWh
|
$0.061 | |
| Electricity Demand | $279,190 | 15,631 |
kW-mo/yr
|
$17.86 | |
| Electricity Fees | $5,883 | - |
|
- | |
| Natural Gas | $124,047 | 13,968 |
MMBtu
|
$8.88 | |
| Waste Disposal Costs | |||||
| Water Usage | $30,557 | 1,601 |
Tgal
|
$19.09 | |
| TOTAL YEARLY COSTS | $678,952 | ||||
| RECOMMENDED SAVINGS* | $131,295 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $95,638 | $904,044 |
$84,247
1,376,414
kWh
|
$11,391
-
kW-mo/yr
|
- | - | |
| 02 | 2.7492: Use proper thickness of insulation on building envelope | $3,123 | $2,092 |
$3,123
51,015
kWh
|
- | - | - | |
| 03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,707 | $1,549 |
$1,707
27,891
kWh
|
- | - | - | |
| 04 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $1,189 | $7,205 |
$1,189
19,422
kWh
|
- | - | - | |
| 05 | 2.8121: Apply for tax-free status for energy purchases | $29,541 | $8,000 | - | - | - | $29,541 | |
| 06 | 2.2136: Install / repair insulation on steam lines | $97 | $50 | - | - |
$97
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $131,295 | $922,940 |
$90,266
1,474,742
kWh
|
$11,391
-
kW-mo/yr
|
$97
-
MMBtu
|
$29,541 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs