| Assessment Year | 2021 |
|---|---|
| Principal Product | High pressure fittings and valves |
| NAICS | 332919: Other Metal Valve and Pipe Fitting Manufacturing |
| SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
110,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | South Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $188,858 | 4,778,908 |
kWh
|
$0.040 | |
| Electricity Demand | $134,585 | 11,514 |
kW-mo/yr
|
$11.69 | |
| Electricity Fees | $2,718 | - |
|
- | |
| Natural Gas | $7,967 | 11,117 |
MMBtu
|
$0.72 | |
| Waste Disposal Costs | |||||
| Water Usage | $7,300 | 1,671,914 |
Tgal
|
$0.004 | |
| Water Disposal | $11,603 | 1,671,914 |
Tgal
|
$0.007 | |
| TOTAL YEARLY COSTS | $353,031 | ||||
| RECOMMENDED SAVINGS* | $92,061 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $70,964 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,209 | $27,253 |
$4,429
112,083
kWh
|
$3,779
-
kW-mo/yr
|
- | |
| 02 | 2.8123: Pay utility bills on time | $812 | - | - | - | $812 | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $69,803 | - |
$69,803
1,766,318
kWh
|
- | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,873 | $15,000 |
$3,873
98,001
kWh
|
- | - | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $349 | $520 |
$349
8,841
kWh
|
- | - | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $9,015 | - |
$9,015
228,113
kWh
|
- | - | |
| TOTAL RECOMMENDED | $92,061 | $42,773 |
$87,470
2,213,356
kWh
|
$3,779
-
kW-mo/yr
|
$812 | ||
| TOTAL IMPLEMENTED | $70,964 | $520 |
$70,152
1,775,159
kWh
|
- | $812 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs