| Assessment Year | 2026 |
|---|---|
| Principal Product | Theater |
| NAICS | 512131: Motion Picture Theaters (except Drive-Ins) |
| SIC | 7832: Motion Picture Theaters, Except Drive-In |
| Sales Range | $5 M to 10M |
| # of Employees | 97 |
| Plant Area |
25,897
ft2
|
| Annual Production | 50
units
|
| Production Hrs. Annual | 5,460
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $107,608 | 578,960 |
kWh
|
$0.19 | |
| Electricity Demand | $33,969 | 2,073 |
kW-mo/yr
|
$16.39 | |
| Electricity Fees | $18,249 | - |
|
- | |
| Natural Gas | $541 | 18 |
MMBtu
|
$30.06 | |
| Other Gas | $274 | 1 |
MMBtu
|
$274.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $10,776 | 708 |
Tgal
|
$15.22 | |
| Water Disposal | $6,877 | 708 |
Tgal
|
$9.71 | |
| Other Liquid (non-haz) | $1,611 | 1 |
gal
|
$1,611.00 | |
| TOTAL YEARLY COSTS | $179,905 | ||||
| RECOMMENDED SAVINGS* | $57,546 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7262: Separate controls of air handlers from ac/ heating systems | $14,994 | $400 |
$14,994
80,655
kWh
|
- | |
| 02 | 2.7262: Separate controls of air handlers from ac/ heating systems | $14,187 | $10,300 |
$11,886
63,936
kWh
|
$2,301
-
kW-mo/yr
|
|
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $13,109 | $30,500 |
$13,109
70,501
kWh
|
- | |
| 04 | 2.7131: Add area lighting switches | $6,398 | $60,000 |
$6,398
34,414
kWh
|
- | |
| 05 | 2.7135: Install occupancy sensors | $3,324 | $3,600 |
$3,048
16,400
kWh
|
$276
-
kW-mo/yr
|
|
| 06 | 2.7134: Use photocell controls | $1,883 | $1,749 |
$941
5,060
kWh
|
$942
-
kW-mo/yr
|
|
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,849 | $4,000 |
$1,849
9,947
kWh
|
- | |
| 08 | 2.4133: Use most efficient type of electric motors | $1,802 | $820 |
$1,586
8,530
kWh
|
$216
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $57,546 | $111,369 |
$53,811
289,443
kWh
|
$3,735
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs