Assessment Year | 2016 |
---|---|
Principal Product | Planter assembly discs |
NAICS | 332216: Saw Blade and Handtool Manufacturing |
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 34 |
Plant Area |
38,145
ft2
|
Annual Production | 789,900
pieces
|
Production Hrs. Annual | 3,240
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,552 | 806,567 |
kWh
|
$0.054 |
Electricity Demand | $17,842 | 2,212 |
kW-mo/yr
|
$8.07 |
Electricity Fees | $768 | - |
|
- |
Natural Gas | $46,241 | 9,034 |
MMBtu
|
$5.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $195,604 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $190,052 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,155 | $9,455 |
$3,228
59,767
kWh
|
$927
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,096 | $840 |
$1,628
30,139
kWh
|
$468
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.2442: Preheat combustion air with waste heat | $1,149 | $2,000 |
$(-503.0)
(-9,310)
kWh
|
$(-144.0)
-
kW-mo/yr
|
$1,796
-
MMBtu
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $738 | $825 |
$488
9,027
kWh
|
$250
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $507 | $600 |
$378
6,996
kWh
|
$129
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $152 | $184 |
$72
1,332
kWh
|
$14
-
kW-mo/yr
|
- | $29 | - | $37 | |
07 | 3.2121: Convert to electrostatic powder coating | $186,807 | $160,000 | - | - |
$(-3,609.0)
-
MMBtu
|
- | $190,416 | - | |
TOTAL RECOMMENDED | $195,604 | $173,904 |
$5,291
97,951
kWh
|
$1,644
-
kW-mo/yr
|
$(-1,813.0)
-
MMBtu
|
$29 | $190,416 | $37 | ||
TOTAL IMPLEMENTED | $190,052 | $162,840 |
$1,125
20,829
kWh
|
$324
-
kW-mo/yr
|
$(-1,813.0)
-
MMBtu
|
- | $190,416 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs