Assessment Year | 2012 |
---|---|
Principal Product | Farm machinery |
NAICS | 333111: Farm Machinery and Equipment Manufacturing |
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
120,000
ft2
|
Annual Production | 250
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,901 | 468,780 |
kWh
|
$0.092 |
Electricity Fees | $931 | - |
|
- |
LPG | $54,340 | 3,090 |
MMBtu
|
$17.59 |
Fuel Oil #2 | $1,618 | 63 |
MMBtu
|
$25.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $37,153 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $923 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|
01 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $19,742 | $54,000 |
$(-13,322.0)
(-145,600)
kWh
|
$31,446
-
MMBtu
|
$1,618
-
MMBtu
|
|
02 | 2.7231: Use radiant heater for spot heating | $7,374 | $17,400 | - |
$7,374
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,576 | $11,333 |
$4,576
50,047
kWh
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,552 | $20 |
$1,552
16,604
kWh
|
- | - | |
05 | 2.7135: Install occupancy sensors | $1,520 | $1,275 |
$1,520
16,609
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $923 | $100 |
$923
10,093
kWh
|
- | - | |
07 | 2.4133: Use most efficient type of electric motors | $757 | $1,700 |
$757
8,277
kWh
|
- | - | |
08 | 2.7134: Use photocell controls | $709 | $800 |
$709
7,584
kWh
|
- | - | |
TOTAL RECOMMENDED | $37,153 | $86,628 |
$(-3,285.0)
(-36,386)
kWh
|
$38,820
-
MMBtu
|
$1,618
-
MMBtu
|
||
TOTAL IMPLEMENTED | $923 | $100 |
$923
10,093
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs