| Assessment Year | 2024 |
|---|---|
| Principal Product | physical recreations |
| NAICS | 713940: Fitness and Recreational Sports Centers |
| SIC | 7991: Physical Fitness Facilities |
| Sales Range | $500 k to 1M |
| # of Employees | 75 |
| Plant Area |
53,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 5,300
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $123,118 | 1,297,760 |
kWh
|
$0.095 |
| Electricity Demand | $22,881 | 2,641 |
kW-mo/yr
|
$8.66 |
| Electricity Fees | $16,829 | - |
|
- |
| Natural Gas | $19,719 | 2,665 |
MMBtu
|
$7.40 |
| Other Gas | $2,357 | 1 |
MMBtu
|
$2,357.00 |
| TOTAL YEARLY COSTS | $184,904 | |||
| RECOMMENDED SAVINGS* | $70,120 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $61,574 | $440,495 |
$58,387
614,602
kWh
|
$3,187
-
kW-mo/yr
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,677 | $6,857 |
$5,085
53,534
kWh
|
$823
-
kW-mo/yr
|
- | $769 | |
| 03 | 4.821: Pay bills on time to avoid late fees | $1,087 | $70 | - | - | $1,087 | - | |
| 04 | 2.6211: Conserve energy by efficient use of vending machines | $548 | $747 |
$461
4,856
kWh
|
$87
-
kW-mo/yr
|
- | - | |
| 05 | 2.7272: Install heat pipes / raise cooling setpoint | $234 | $80 |
$169
1,778
kWh
|
$65
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $70,120 | $448,249 |
$64,102
674,770
kWh
|
$4,162
-
kW-mo/yr
|
$1,087 | $769 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs