Assessment Year | 2019 |
---|---|
Principal Product | Commercial paper rolls |
NAICS | 322121: Paper (except Newsprint) Mills |
SIC | 2621: Paper Mills |
Sales Range | $10 M to 50M |
# of Employees | 132 |
Plant Area |
350,000
ft2
|
Annual Production | 3,300,000
units
|
Production Hrs. Annual | 6,069
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $200,314 | 3,230,883 |
kWh
|
$0.062 |
Electricity Demand | $148,996 | 10,383 |
kW-mo/yr
|
$14.35 |
TOTAL YEARLY COSTS | $349,310 | |||
RECOMMENDED SAVINGS* | $76,753 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $64,356 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $47,588 | $48,177 |
$33,520
540,691
kWh
|
$14,068
-
kW-mo/yr
|
|
02 | 2.7232: Replace existing hvac unit with high efficiency model | $12,397 | $53,000 |
$6,485
104,580
kWh
|
$5,912
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,754 | $16,690 |
$7,378
119,000
kWh
|
$3,376
-
kW-mo/yr
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,014 | $200 |
$4,126
66,555
kWh
|
$1,888
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $76,753 | $118,067 |
$51,509
830,826
kWh
|
$25,244
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $64,356 | $65,067 |
$45,024
726,246
kWh
|
$19,332
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs