Assessment Year | 2018 |
---|---|
Principal Product | Commercial paper rolls |
NAICS | 322230: Stationery Product Manufacturing |
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
20,000
ft2
|
Annual Production | 900,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $80,709 | 736,800 |
kWh
|
$0.11 |
Electricity Demand | $17,468 | 2,441 |
kW-mo/yr
|
$7.16 |
Electricity Fees | $3,317 | - |
|
- |
Other Gas | $18,000 | 697 |
MMBtu
|
$25.82 |
TOTAL YEARLY COSTS | $119,494 | |||
RECOMMENDED SAVINGS* | $174,335 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $150,435 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,307 | $180 |
$6,491
59,280
kWh
|
$816
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,768 | $800 |
$6,012
54,912
kWh
|
$756
-
kW-mo/yr
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $18,097 | $36,012 |
$16,030
146,388
kWh
|
$2,067
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,551 | $12,598 |
$10,551
96,353
kWh
|
- | - | - | |
05 | 4.111: Add equipment/ operators to reduce production bottleneck | $114,480 | $30,000 |
$3,160
28,875
kWh
|
- | - | $111,320 | |
06 | 4.131: Modify process to reduce material use/cost | $1,556 | - |
$201
1,835
kWh
|
- | - | $1,355 | |
07 | 4.821: Pay bills on time to avoid late fees | $15,576 | - | - | - | $15,576 | - | |
TOTAL RECOMMENDED | $174,335 | $79,590 |
$42,445
387,643
kWh
|
$3,639
-
kW-mo/yr
|
$15,576 | $112,675 | ||
TOTAL IMPLEMENTED | $150,435 | $78,790 |
$36,232
330,896
kWh
|
$2,883
-
kW-mo/yr
|
- | $111,320 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs