| Assessment Year | 1999 |
|---|---|
| Principal Product | Diffusers and Air Handlers |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 470 |
| Plant Area |
262,000
ft2
|
| Annual Production | 2,000,000
ton
|
| Production Hrs. Annual | 5,900
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $336,772 | 4,820,047 |
kWh
|
$0.070 |
| Electricity Demand | $78,307 | 12,648 |
kW-mo/yr
|
$6.19 |
| Electricity Fees | $36,636 | - |
|
- |
| Natural Gas | $141,156 | 24,596 |
MMBtu
|
$5.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $49,473 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $24,135 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $689 | $696 |
$401
5,862
kWh
|
$58
-
kW-mo/yr
|
- | $114 | $116 | |
| 02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $7,274 | $1,040 |
$7,274
104,924
kWh
|
- | - | - | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,741 | $120 |
$7,585
109,613
kWh
|
$1,156
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,394 | $1,000 |
$12,687
183,177
kWh
|
$2,707
-
kW-mo/yr
|
- | - | - | |
| 05 | 3.6192: Use a less expensive method of waste removal | $720 | $30 | - | - |
$720
-
lb
|
- | - | |
| 06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $14,688 | $12,256 | - | - |
$14,688
-
lb
|
- | - | |
| 07 | 4.111: Add equipment/ operators to reduce production bottleneck | $1,967 | $180 | - | - | - | $1,967 | - | |
| TOTAL RECOMMENDED | $49,473 | $15,322 |
$27,947
403,576
kWh
|
$3,921
-
kW-mo/yr
|
$15,408
-
lb
|
$2,081 | $116 | ||
| TOTAL IMPLEMENTED | $24,135 | $1,120 |
$20,272
292,790
kWh
|
$3,863
-
kW-mo/yr
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs