Assessment Year | 1994 |
---|---|
Principal Product | concrete |
NAICS |
n/a
|
SIC | 3273: Ready-Mixed Concrete |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
100,000
ft2
|
Annual Production | 1,000,000
ton
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $266,578 | 4,659,144 |
kWh
|
$0.057 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,079 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,620 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $10,657 | $20,486 |
$10,657
186,401
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,311 | - |
$3,311
57,737
kWh
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $491 | - |
$491
8,499
kWh
|
|
04 | 2.4314: Use synthetic lubricant | $1,459 | $2,459 |
$1,459
7,327
kWh
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $769 | $200 |
$769
13,482
kWh
|
|
06 | 2.2612: Use cooling tower water instead of refrigeration | $1,424 | $3,000 |
$1,424
24,912
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,341 | $7,356 |
$2,341
41,032
kWh
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $414 | $698 |
$414
7,327
kWh
|
|
09 | 2.8114: Change rate schedules or other changes in utility service | $12,213 | $25,250 |
$12,213
-
kWh
|
|
TOTAL RECOMMENDED | $33,079 | $59,449 |
$33,079
346,717
kWh
|
||
TOTAL IMPLEMENTED | $17,620 | $26,145 |
$17,620
289,859
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs