Assessment Year | 1992 |
---|---|
Principal Product | PLASTIC INJECTION MOLDS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $475,294 | 8,406,213 |
kWh
|
$0.057 |
Natural Gas | $10,705 | 2,177 |
MMBtu
|
$4.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $81,803 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $19,891 | $70,000 |
$19,891
351,700
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,159 | $2,365 |
$1,159
20,516
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $29,882 | $8,320 |
$29,882
528,429
kWh
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,780 | $653 |
$6,780
119,871
kWh
|
- | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,242 | $432 |
$2,242
39,566
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $4,186 | $21,367 |
$4,186
74,150
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $415 | $100 |
$415
7,327
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,336 | $10,325 |
$3,513
62,134
kWh
|
$(-177.0) | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $525 | $61 |
$570
9,965
kWh
|
$(-45.0) | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,268 | $7,024 |
$13,268
234,760
kWh
|
- | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $119 | $300 |
$119
2,052
kWh
|
- | |
TOTAL RECOMMENDED | $81,803 | $120,947 |
$82,025
1,450,470
kWh
|
$(-222.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs