| Assessment Year | 1999 |
|---|---|
| Principal Product | Injection molding |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
131,250
ft2
|
| Annual Production | 15,000
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $339,968 | 12,793,377 |
kWh
|
$0.027 |
| Electricity Demand | $230,570 | 21,742 |
kW-mo/yr
|
$10.60 |
| Natural Gas | $14,777 | 2,902 |
MMBtu
|
$5.09 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $39,771 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $440 | $767 | n/a |
$262
9,672
kWh
|
$178
-
kW-mo/yr
|
- | - |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $91 | - | n/a |
$55
2,052
kWh
|
$36
-
kW-mo/yr
|
- | - |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $2,463 | $4,772 | n/a |
$1,545
57,151
kWh
|
$918
-
kW-mo/yr
|
- | - |
| 04 | 2.2511: Insulate bare equipment | $22,777 | $3,207 | n/a |
$6,946
155,627
kWh
|
$3,168
-
kW-mo/yr
|
- | $12,663 |
| 05 | 4.423: Move product using mechanical means | $14,000 | $32,400 | n/a | - | - | $14,000 | - |
| TOTAL RECOMMENDED | $39,771 | $41,146 |
$8,808
224,502
kWh
|
$4,300
-
kW-mo/yr
|
$14,000 | $12,663 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs