Assessment Year 2023
Principal Product fiberglass underground storage tanks
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3999: Manufacturing Industries, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 90
Plant Area 50,000
ft2
Annual Production 750
pieces
Production Hrs. Annual 6,498
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $95,518 1,479,120
kWh
Electricity Demand $25,941 3,847
kW-mo/yr
Electricity Fees $24,719 -
Natural Gas $39,589 3,669
MMBtu
TOTAL YEARLY COSTS $185,767
RECOMMENDED SAVINGS* $60,912 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $60,047

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $47,100 $10,000 - - $9,420 $37,680
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,700 $1,000 $5,500
85,200
kWh
$1,200
-
kW-mo/yr
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $3,490 $4,220 $2,860
44,310
kWh
$630
-
kW-mo/yr
- -
04 2.3212: Optimize plant power factor $2,710 $7,275 - $2,710
-
kW-mo/yr
- -
05 2.7135: Install occupancy sensors $525 $390 $525
8,140
kWh
- - -
06 2.4314: Use synthetic lubricant $340 $980 $280
4,270
kWh
$60
-
kW-mo/yr
- -
07 2.7134: Use photocell controls $47 $165 $35
548
kWh
$12
-
kW-mo/yr
- -
TOTAL RECOMMENDED $60,912 $24,030 $9,200
142,468
kWh
$4,612
-
kW-mo/yr
$9,420 $37,680
TOTAL IMPLEMENTED $60,047 $22,660 $8,395
130,058
kWh
$4,552
-
kW-mo/yr
$9,420 $37,680
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs