Assessment Year | 2023 |
---|---|
Principal Product | High school students |
NAICS | 611110: Elementary and Secondary Schools |
SIC | 8211: Elementary and Secondary Schools |
Sales Range | $1 M to 5M |
# of Employees | 25 |
Plant Area |
44,852
ft2
|
Annual Production | 100
units
|
Production Hrs. Annual | 2,436
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,104 | 634,176 |
kWh
|
$0.10 |
Electricity Fees | $66,104 | - |
|
- |
Natural Gas | $4,484 | 505 |
MMBtu
|
$8.88 |
TOTAL YEARLY COSTS | $136,692 | |||
RECOMMENDED SAVINGS* | $42,862 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,889 | $41,673 |
$4,889
46,920
kWh
|
|
02 | 2.7135: Install occupancy sensors | $2,074 | $8,875 |
$2,074
19,902
kWh
|
|
03 | 2.9114: Use solar heat to make electricty | $35,899 | $383,268 |
$35,899
344,517
kWh
|
|
TOTAL RECOMMENDED | $42,862 | $433,816 |
$42,862
411,339
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs