Assessment Year | 2019 |
---|---|
Principal Product | Polyethylene film and bags |
NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $100 M to 500M |
# of Employees | 223 |
Plant Area |
365,000
ft2
|
Annual Production | 120,000,000
lb
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,157,565 | 38,077,815 |
kWh
|
$0.030 | |
Electricity Demand | $547,184 | 69,696 |
kW-mo/yr
|
$7.85 | |
Electricity Fees | $42,336 | - |
|
- | |
Natural Gas | $57,155 | 8,243 |
MMBtu
|
$6.93 | |
Waste Disposal Costs | |||||
Water Usage | $15,596 | 2,047 |
Tgal
|
$7.62 | |
TOTAL YEARLY COSTS | $1,819,836 | ||||
RECOMMENDED SAVINGS* | $86,469 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $40,439 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $46,030 | $25,900 |
$32,300
1,059,400
kWh
|
$13,730
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,200 | $60,000 |
$14,200
465,000
kWh
|
$6,000
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,400 | $2,000 |
$8,200
271,200
kWh
|
$3,200
-
kW-mo/yr
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,155 | $38 |
$4,480
146,400
kWh
|
$1,675
-
kW-mo/yr
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,244 | - |
$1,318
43,213
kWh
|
$926
-
kW-mo/yr
|
|
06 | 2.7111: Reduce illumination to minimum necessary levels | $440 | $100 |
$250
8,300
kWh
|
$190
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $86,469 | $88,038 |
$60,748
1,993,513
kWh
|
$25,721
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $40,439 | $62,138 |
$28,448
934,113
kWh
|
$11,991
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs