Assessment Year 2018
Principal Product Compressor rings and gaskets
NAICS 339991: Gasket, Packing, and Sealing Device Manufacturing
SIC 3053: Gaskets, Packing, and Sealing Devices
Sales Range $10
M
to 50
M
# of Employees 40
Plant Area 70,000
ft2
Annual Production 500,000
lb
Production Hrs. Annual 2,380
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $86,209 2,045,221
kWh
Electricity Demand $64,679 5,499
kW-mo/yr
Electricity Fees $3,254 -
Natural Gas $40,288 5,026
MMBtu
TOTAL YEARLY COSTS $194,430
RECOMMENDED SAVINGS* $38,900 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
01 2.3212: Optimize plant power factor $17,280 $17,230 - $17,280
-
kW-mo/yr
- -
02 2.8121: Apply for tax-free status for energy purchases $13,320 $2,000 - - $2,664 $10,656
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,120 $1,000 $1,060
26,180
kWh
$2,060
-
kW-mo/yr
- -
04 2.6218: Turn off equipment when not in use $3,100 - $3,100
76,300
kWh
- - -
05 2.7124: Make a practice of turning off lights when not needed $1,260 - $1,260
31,100
kWh
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $820 $3,460 $820
20,230
kWh
- - -
TOTAL RECOMMENDED $38,900 $23,690 $6,240
153,810
kWh
$19,340
-
kW-mo/yr
$2,664 $10,656
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs