ITAC Assessment: AM0755
ITAC logo
ITAC Assessment: AM0755
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Wheelchair accessories
NAICS 339999: All Other Miscellaneous Manufacturing
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 50,000
ft2
Annual Production 1,500,000
pieces
Production Hrs. Annual 6,024
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $95,535 939,696
kWh
Electricity Demand $6,494 3,243
kW-mo/yr
Waste Disposal Costs
Water Usage $5,419 775
Tgal
Water Disposal $5,820 775
Tgal
TOTAL YEARLY COSTS $113,268
RECOMMENDED SAVINGS* $5,660 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,360

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings
01 4.611: Begin a practice of predictive / preventative maintenance $450 $1,970 $880
8,500
kWh
$60
-
kW-mo/yr
$590 $(-1,080.0)
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,310 $3,750 $1,180
11,300
kWh
$130
-
kW-mo/yr
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,175 $500 $1,130
10,840
kWh
$45
-
kW-mo/yr
- -
04 2.4239: Eliminate or reduce compressed air usage $1,040 $1,070 $1,040
10,000
kWh
- - -
05 2.7135: Install occupancy sensors $555 $540 $555
5,350
kWh
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $425 $205 $122
1,180
kWh
$3
-
kW-mo/yr
$300 -
07 2.7111: Reduce illumination to minimum necessary levels $450 $30 $430
4,130
kWh
$20
-
kW-mo/yr
- -
08 2.4231: Reduce the pressure of compressed air to the minimum required $255 $4 $235
2,250
kWh
$20
-
kW-mo/yr
- -
TOTAL RECOMMENDED $5,660 $8,069 $5,572
53,550
kWh
$278
-
kW-mo/yr
$890 $(-1,080.0)
TOTAL IMPLEMENTED $3,360 $4,485 $2,862
27,450
kWh
$198
-
kW-mo/yr
$300 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs