Assessment Year | 2015 |
---|---|
Principal Product | Industrial Laundry & Sewing |
NAICS | 314999: All Other Miscellaneous Textile Product Mills |
SIC | 2326: Men's and Boys' Work Clothing |
Sales Range | $1 M to 5M |
# of Employees | 62 |
Plant Area |
30,000
ft2
|
Annual Production | 6,000,000
lb
|
Production Hrs. Annual | 3,205
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,303 | 554,158 |
kWh
|
$0.073 |
Electricity Demand | $18,985 | 2,500 |
kW-mo/yr
|
$7.59 |
Natural Gas | $103,904 | 19,223 |
MMBtu
|
$5.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,930 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,085 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2441: Preheat boiler makeup water with waste process heat | $23,350 | $24,500 | - | - |
$23,350
-
MMBtu
|
|
02 | 2.3212: Optimize plant power factor | $4,070 | $3,950 | - |
$4,070
-
kW-mo/yr
|
- | |
03 | 2.2113: Repair or replace steam traps | $2,350 | $440 | - | - |
$2,350
-
MMBtu
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,420 | $5 |
$940
14,915
kWh
|
$480
-
kW-mo/yr
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,185 | $500 | - | - |
$1,185
-
MMBtu
|
|
06 | 2.2123: Insulate feedwater tank | $950 | $140 | - | - |
$950
-
MMBtu
|
|
07 | 2.7145: Install skylights | $625 | $970 |
$625
9,900
kWh
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $550 | $275 |
$370
5,900
kWh
|
$180
-
kW-mo/yr
|
- | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $430 | - |
$265
4,200
kWh
|
$165
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $34,930 | $30,780 |
$2,200
34,915
kWh
|
$4,895
-
kW-mo/yr
|
$27,835
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,085 | $1,215 |
$370
5,900
kWh
|
$180
-
kW-mo/yr
|
$3,535
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs