Assessment Year | 2014 |
---|---|
Principal Product | Wooden prehung and steel doors |
NAICS | 321918: Other Millwork (including Flooring) |
SIC | 2431: Millwork |
Sales Range | $50 M to 100M |
# of Employees | 148 |
Plant Area |
175,000
ft2
|
Annual Production | 912,000
pieces
|
Production Hrs. Annual | 4,267
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $59,182 | 1,247,800 |
kWh
|
$0.047 |
Electricity Demand | $20,956 | 2,865 |
kW-mo/yr
|
$7.31 |
Electricity Fees | $9,246 | - |
|
- |
Natural Gas | $5,506 | 694 |
MMBtu
|
$7.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $83,835 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $70,360 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,280 | $17,710 |
$19,110
406,700
kWh
|
$8,170
-
kW-mo/yr
|
- | - | - | - | |
02 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $11,930 | $4,000 | - | - | - |
$(-460.0)
-
MMBtu
|
$12,390
-
Tgal
|
- | |
03 | 2.8121: Apply for tax-free status for energy purchases | $34,980 | $10,000 | - | - | $6,996 | - | - | $27,984 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,080 | $2,000 |
$4,260
90,700
kWh
|
$1,820
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4322: Use or replace with energy efficient substitutes | $2,020 | $1,485 |
$1,420
30,200
kWh
|
$600
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,235 | $10 |
$865
18,400
kWh
|
$370
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.7124: Make a practice of turning off lights when not needed | $310 | - |
$210
4,480
kWh
|
$100
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $83,835 | $35,205 |
$25,865
550,480
kWh
|
$11,060
-
kW-mo/yr
|
$6,996 |
$(-460.0)
-
MMBtu
|
$12,390
-
Tgal
|
$27,984 | ||
TOTAL IMPLEMENTED | $70,360 | $31,195 |
$24,790
527,600
kWh
|
$10,590
-
kW-mo/yr
|
$6,996 | - | - | $27,984 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs