| Assessment Year | 2012 |
|---|---|
| Principal Product | Oil field equipment |
| NAICS | 332216: Saw Blade and Handtool Manufacturing |
| SIC | 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 188 |
| Plant Area |
110,000
ft2
|
| Annual Production | 175,000
pieces
|
| Production Hrs. Annual | 3,024
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $223,632 | 2,736,444 |
kWh
|
$0.082 |
| Electricity Demand | $38,436 | 6,684 |
kW-mo/yr
|
$5.75 |
| Electricity Fees | $14,664 | - |
|
- |
| Natural Gas | $6,521 | 666 |
MMBtu
|
$9.79 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $70,296 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $53,011 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $18,020 | $300 |
$14,600
175,000
kWh
|
$3,420
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7145: Install skylights | $11,600 | $34,400 |
$11,600
137,200
kWh
|
- | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,270 | $17,600 |
$7,000
79,900
kWh
|
$1,270
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,600 | $500 |
$5,900
74,000
kWh
|
$1,700
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.8121: Apply for tax-free status for energy purchases | $15,800 | - | - | - | $5,300 | - | $10,500 | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $3,400 | $4,500 |
$3,400
42,700
kWh
|
- | - | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,776 | $1,700 |
$660
8,200
kWh
|
$66
-
kW-mo/yr
|
- | $2,050 | - | |
| 08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,940 | $105 |
$1,500
19,100
kWh
|
$440
-
kW-mo/yr
|
- | - | - | |
| 09 | 2.7135: Install occupancy sensors | $545 | $130 |
$545
5,170
kWh
|
- | - | - | - | |
| 10 | 2.8123: Pay utility bills on time | $345 | - | - | - | $345 | - | - | |
| TOTAL RECOMMENDED | $70,296 | $59,235 |
$45,205
541,270
kWh
|
$6,896
-
kW-mo/yr
|
$5,645 | $2,050 | $10,500 | ||
| TOTAL IMPLEMENTED | $53,011 | $20,230 |
$28,705
342,270
kWh
|
$6,456
-
kW-mo/yr
|
$5,300 | $2,050 | $10,500 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs