| Assessment Year | 2010 |
|---|---|
| Principal Product | Truck trailers |
| NAICS | 336212: Truck Trailer Manufacturing |
| SIC | 3715: Truck Trailers |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
272,000
ft2
|
| Annual Production | 324
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $221,211 | 2,538,178 |
kWh
|
$0.087 |
| Electricity Demand | $90,917 | 12,026 |
kW-mo/yr
|
$7.56 |
| Natural Gas | $58,799 | 6,063 |
MMBtu
|
$9.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,765 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,425 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,200 | $34,000 |
$6,800
75,500
kWh
|
$3,400
-
kW-mo/yr
|
- | - | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $6,050 | - |
$4,100
45,565
kWh
|
$1,950
-
kW-mo/yr
|
- | - | |
| 03 | 2.8123: Pay utility bills on time | $1,925 | - | - | - | $1,925 | - | |
| 04 | 2.3212: Optimize plant power factor | $1,200 | $3,250 | - |
$1,200
-
kW-mo/yr
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,025 | $460 |
$260
2,900
kWh
|
$30
-
kW-mo/yr
|
- | $735 | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $800 | $400 |
$530
5,900
kWh
|
$270
-
kW-mo/yr
|
- | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $725 | $350 |
$485
5,400
kWh
|
$240
-
kW-mo/yr
|
- | - | |
| 08 | 2.7124: Make a practice of turning off lights when not needed | $500 | - |
$500
5,560
kWh
|
- | - | - | |
| 09 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $340 | - | - | - | - | $340 | |
| TOTAL RECOMMENDED | $22,765 | $38,460 |
$12,675
140,825
kWh
|
$7,090
-
kW-mo/yr
|
$1,925 | $1,075 | ||
| TOTAL IMPLEMENTED | $22,425 | $38,460 |
$12,675
140,825
kWh
|
$7,090
-
kW-mo/yr
|
$1,925 | $735 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs