Assessment Year | 2003 |
---|---|
Principal Product | Textiles and fabrics |
NAICS | 313210: Broadwoven Fabric Mills |
SIC | 2211: Broadwoven Fabric Mills, Cotton |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 144,900,000
thousand feet
|
Production Hrs. Annual | 8,520
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,227,100 | 46,318,700 |
kWh
|
$0.048 |
Natural Gas | $789,500 | 167,600 |
MMBtu
|
$4.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $169,595 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $41,405 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.112: Replace old machine with new automatic multi-station tool | $122,000 | $2,050,000 | n/a | - | $122,000 | - | - |
02 | 4.821: Pay bills on time to avoid late fees | $15,830 | - | - | - | $15,830 | - | |
03 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $8,000 | $800 | - | - | - | $8,000 | |
04 | 4.132: Purchase new equipment to reduce material use / cost | $7,300 | $89,640 | - | - | - | $7,300 | |
05 | 2.4314: Use synthetic lubricant | $4,520 | - |
$4,520
96,200
kWh
|
- | - | - | |
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $3,510 | - |
$3,510
68,220
kWh
|
- | - | - | |
07 | 3.1291: Eliminate practice of mixing waste streams | $3,500 | - | - | - | - | $3,500 | |
08 | 2.7124: Make a practice of turning off lights when not needed | $2,300 | - |
$2,300
49,000
kWh
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,670 | $1,440 |
$1,140
24,300
kWh
|
$530 | - | - | |
10 | 2.8121: Apply for tax-free status for energy purchases | $965 | $800 | - | - | $965 | - | |
TOTAL RECOMMENDED | $169,595 | $2,142,680 |
$11,470
237,720
kWh
|
$122,530 | $16,795 | $18,800 | ||
TOTAL IMPLEMENTED | $41,405 | $91,240 |
$5,810
117,220
kWh
|
- | $16,795 | $18,800 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs