| Assessment Year | 1995 |
|---|---|
| Principal Product | Air cooled heat exchangers |
| NAICS |
n/a
|
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $50 M to 100M |
| # of Employees | 265 |
| Plant Area |
248,855
ft2
|
| Annual Production | 5,570
thousand feet
|
| Production Hrs. Annual | 2,510
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $499,711 | 6,979,484 |
kWh
|
$0.072 |
| Natural Gas | $109,655 | 33,294 |
MMBtu
|
$3.29 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,930 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $32,930 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 3.7134: Wash and reuse rags on-site | $25,010 | $7,900 | - | - |
$25,010
-
lb
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,750 | $2,400 |
$4,750
115,768
kWh
|
- | - | |
| 03 | 2.2121: Increase amount of condensate returned | $1,790 | $2,800 | - |
$1,790
-
MMBtu
|
- | |
| 04 | 2.7134: Use photocell controls | $950 | $285 |
$950
13,775
kWh
|
- | - | |
| 05 | 2.7124: Make a practice of turning off lights when not needed | $260 | - |
$260
6,155
kWh
|
- | - | |
| 06 | 2.4314: Use synthetic lubricant | $170 | - |
$170
2,345
kWh
|
- | - | |
| TOTAL RECOMMENDED | $32,930 | $13,385 |
$6,130
138,043
kWh
|
$1,790
-
MMBtu
|
$25,010
-
lb
|
||
| TOTAL IMPLEMENTED | $32,930 | $13,385 |
$6,130
138,043
kWh
|
$1,790
-
MMBtu
|
$25,010
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs