Assessment Year | 1991 |
---|---|
Principal Product | DOOR JAMS, STEPS, & TRIM |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 320 |
Plant Area |
n/a
|
Annual Production | 11,000
thousand feet
|
Production Hrs. Annual | 4,310
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $140,503 | 1,869,871 |
kWh
|
$0.075 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,427 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4131: Size electric motors for peak operating efficiency | $9,280 | $19,700 |
$9,280
128,957
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,148 | $653 |
$1,148
15,826
kWh
|
|
03 | 2.5121: Redesign flow to minimize mass transfer length | $4,979 | $16,000 |
$4,979
66,237
kWh
|
|
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,370 | - |
$3,370
65,064
kWh
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,161 | $500 |
$1,161
22,567
kWh
|
|
06 | 2.4312: Improve lubrication practices | $1,109 | - |
$1,109
15,240
kWh
|
|
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $240 | - |
$240
4,689
kWh
|
|
08 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $140 | $55 |
$140
1,465
kWh
|
|
TOTAL RECOMMENDED | $21,427 | $36,908 |
$21,427
320,045
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs