Assessment Year 1991
Principal Product DOOR JAMS, STEPS, & TRIM
NAICS
n/a
SIC 2431: Millwork
Sales Range $10
M
to 50
M
# of Employees 320
Plant Area
n/a
Annual Production 11,000
thousand feet
Production Hrs. Annual 4,310
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $140,503 1,869,871
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,427 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4131: Size electric motors for peak operating efficiency $9,280 $19,700 $9,280
128,957
kWh
02 2.4133: Use most efficient type of electric motors $1,148 $653 $1,148
15,826
kWh
03 2.5121: Redesign flow to minimize mass transfer length $4,979 $16,000 $4,979
66,237
kWh
04 2.6212: Turn off equipment during breaks, reduce operating time $3,370 - $3,370
65,064
kWh
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,161 $500 $1,161
22,567
kWh
06 2.4312: Improve lubrication practices $1,109 - $1,109
15,240
kWh
07 2.4231: Reduce the pressure of compressed air to the minimum required $240 - $240
4,689
kWh
08 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $140 $55 $140
1,465
kWh
TOTAL RECOMMENDED $21,427 $36,908 $21,427
320,045
kWh
TOTAL IMPLEMENTED - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs