Assessment Year | 1988 |
---|---|
Principal Product | CORREGATED PAPER CONTAINERS |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 34,200
ton
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $186,318 | 3,546,014 |
kWh
|
$0.053 |
Natural Gas | $126,687 | 31,798 |
MMBtu
|
$3.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,085 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,920 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $9,122 | $4,200 | - |
$9,122
-
MMBtu
|
|
02 | 2.2113: Repair or replace steam traps | $6,137 | $3,360 | - |
$6,137
-
MMBtu
|
|
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $4,915 | $24,000 |
$8,863
232,122
kWh
|
$(-3,948.0)
-
MMBtu
|
|
04 | 2.2511: Insulate bare equipment | $1,928 | $734 | - |
$1,928
-
MMBtu
|
|
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,848 | $270 | - |
$1,848
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,195 | $244 |
$5,195
126,612
kWh
|
- | |
07 | 2.7314: Reduce ventilation air | $3,842 | - |
$3,842
132,767
kWh
|
- | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $939 | $1,750 |
$939
31,653
kWh
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,005 | $3,900 |
$1,005
19,050
kWh
|
- | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $154 | $75 |
$154
2,638
kWh
|
- | |
TOTAL RECOMMENDED | $35,085 | $38,533 |
$19,998
544,842
kWh
|
$15,087
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,920 | $5,455 |
$4,935
167,058
kWh
|
$7,985
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs