| Assessment Year | 1987 |
|---|---|
| Principal Product | LIGHOGRAPHIC PLATES |
| NAICS |
n/a
|
| SIC | 2796: Platemaking and Related Services |
| Sales Range | $10 M to 50M |
| # of Employees | 82 |
| Plant Area |
n/a
|
| Annual Production | 9,000,000
pieces
|
| Production Hrs. Annual | 6,816
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $249,501 | 4,589,977 |
kWh
|
$0.054 |
| Natural Gas | $11,711 | 2,262 |
MMBtu
|
$5.18 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,834 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,655 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $3,552 | $8,250 |
$3,552
-
kWh
|
- | |
| 02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,103 | $3,300 |
$1,103
16,120
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $484 | $145 |
$484
9,965
kWh
|
- | |
| 04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $22,695 | $15,500 |
$47,994
1,073,564
kWh
|
$(-25,299.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $27,834 | $27,195 |
$53,133
1,099,649
kWh
|
$(-25,299.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,655 | $11,550 |
$4,655
16,120
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs