ITAC Assessment: AM0002
ITAC logo
ITAC Assessment: AM0002
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1987
Principal Product BUSINESS FORMS
NAICS
n/a
SIC 2761: Manifold Business Forms
Sales Range $10
M
to 50
M
# of Employees 156
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 2,250
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $267,702 4,867,233
kWh
Natural Gas $70,657 19,338
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $109,532 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $108,889

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $11,479 $5,500 $11,479
260,844
kWh
-
02 2.7226: Use computer programs to optimize hvac performance $95,084 $60,000 $52,212
1,077,960
kWh
$42,872
-
MMBtu
03 2.6212: Turn off equipment during breaks, reduce operating time $205 - $205
4,689
kWh
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $643 $3,224 $643
14,654
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $657 $1,972 $657
8,499
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $154 $332 $154
2,052
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,175 $2,533 $1,175
15,533
kWh
-
08 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $58 $97 $58
1,465
kWh
-
09 2.7111: Reduce illumination to minimum necessary levels $77 $18 $77
1,758
kWh
-
TOTAL RECOMMENDED $109,532 $73,676 $66,660
1,387,454
kWh
$42,872
-
MMBtu
TOTAL IMPLEMENTED $108,889 $70,452 $66,017
1,372,800
kWh
$42,872
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs