13
matching recommendations| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| CO0657 #05 Y:2012 | 05 | 2012 | Use solar heat to make electricty | $2,460 | $35,000 | |
| CO0657 #04 Y:2012 | 04 | 2012 | Utilize higher efficiency lamps and/or ballasts | $460 | $510 | |
| CO0657 #03 Y:2012 | 03 | 2012 | Install timers and/or thermostats | $460 | - | |
| CO0657 #02 Y:2012 | 02 | 2012 | Eliminate leaks in inert gas and compressed air lines/ valves | $2,840 | $350 | |
| CO0657 #01 Y:2012 | 01 | 2012 | Use adjustable frequency drive or multiple speed motors on existing system | $24,210 | $77,390 | |
| CO0576 #08 Y:2005 | 08 | 2005 | Utilize higher efficiency lamps and/or ballasts | $920 | $1,440 | |
| CO0576 #07 Y:2005 | 07 | 2005 | Recover waste heat from equipment | $1,740 | $980 | |
| CO0576 #06 Y:2005 | 06 | 2005 | Improve air circulation with destratification fans / other methods | $4,670 | $9,240 | |
| CO0576 #05 Y:2005 | 05 | 2005 | Replace existing hvac unit with high efficiency model | $6,190 | $17,170 | |
| CO0576 #04 Y:2005 | 04 | 2005 | Utilize outside air instead of conditioned air for drying | $200 | $170 | |
| CO0576 #03 Y:2005 | 03 | 2005 | Eliminate leaks in inert gas and compressed air lines/ valves | $2,540 | $190 | |
| CO0576 #02 Y:2005 | 02 | 2005 | Shift from daytime to nighttime operation | $4,450 | - | |
| CO0576 #01 Y:2005 | 01 | 2005 | Install rotating carousels to reduce set-up times | $84,000 | $30,670 |